WhatsApp

Engineering, sampling and weighing for mining companies in Kazakhstan and Central Asia.

Conveyor protection

The complete BMH belt conveyor protection range: emergency pull-cord and limit switches, belt misalignment monitoring, level and chute blockage sensors. Selection, supply from stock in Kazakhstan, installation and service — BMH Solutions, Astana.

MANUFACTURING, STOCK AND SERVICE IN KAZAKHSTAN
Video · 3 minutes

How conveyor protection works — and what its absence costs

The animation shows how each device trips: PS-31, EPK-30, BRS-2, LS-32 and TS-39. After each one — what happens without it and an approximate loss estimate for a 5,000 t/h plant.

Indicative calculation: 5,000 t/h, Cu 0.35 %, recovery 85 %, LME $12,471/t (18.11.2026), National Bank of Kazakhstan rate 456.83 ₸/$. Human life and health are priceless.

Wiring and SCADA

Dual-channel emergency stop with the exact trip location on the operator screen

Example: a 1 km overland conveyor with a pull-cord switch every 25 m — 41 switches in 10 zones. Click any switch on the mimic diagramto “pull the cord”, then reset it — just as an operator would.

CV-301 · overland conveyor · 1000 m41 × PS-31 · 6 × BRS-2 · speed sensor · 10 zones Z1–Z10 · safety bus
Running · auto
Belt speed3.15 m/ssetpoint 3.15
Throughput2,840 t/hbelt scale
M1 current388 Arated 420 A
Trip location—all zones healthy
Downtime00:00since stop
Lost production0 tat 2,840 t/h
M1 bus 0 m500 m1000 m
Event log
—:—:—3CV301_BUS_OK · bus Z1–Z10: 10/10 nodes online
Start interlocks
Pull-cord PS-31 (41)healthy
Channel discrepancy C1/C2none
Belt misalignment BRS-2 (6)healthy
Speed monitoringhealthy
Safety bus10/10
Local resetnot required
Switch on the stringer
  • PS-31: 2 NC (11-12, 21-22) + 1 NO (13-14)
  • 25 m spacing, cord along the walkway
  • IP65, −45 to +85 °C
Zone box Z1–Z10
  • 4–5 switches per 100 m
  • Cable 5×1.5, up to 25 m
  • Modules: F-DI 8 ch + DI 4 ch, IP66
Safety bus
  • One 2-core cable for the whole conveyor
  • Data + 24 V power
  • PROFIsafe / AS-i Safety — to suit the customer’s PLC
Safety PLC and SCADA
  • Dual-channel monitoring, discrepancy ≤ 0.5 s
  • Drive stop without operator action
  • Tags CV301_PSxx_TRIP, log, acknowledgement
1 cablealong the whole conveyor instead of 41 separate lines to the cabinet
No. and metrethe fitter goes straight to the right switch instead of walking a kilometre
2 channelsa welded contact shows up immediately — the conveyor will not start with a faulty switch
Design a layout for your conveyor →
01 · Conveyor protection switches · CPS series

A reliable stop. Anywhere along the belt.

Heavy-duty pull-cord and limit switches for mining conveyors — built for dust, frost and 24/7 operation. Cast aluminium housing, twin-cam mechanism with separate alarm and stop contacts, convenient terminal block. One housing and one spares kit for both models.

Аварийный тросовый выключатель BMH PS-31
2 in 1One platform: one housing and spares kit for both models
−45 °C−45 to +85 °C, cast IP65 housing
2 + 22 NO + 2 NC with positive opening
₸Prices in tenge, stock and service in Astana
BMH PS-31
PS-31 · one pull — full stop

Emergency pull-cord switch

A steel cord runs along the belt: anyone on the line can stop the conveyor with a single pull. At 18° two cams switch the alarm and stop contacts and the mechanism latches. Reset only with the lever on the switch itself.

ActuationCord, from either side
Trip point18° ± 2°, lever travel up to 30°
LatchingMechanical, manual reset
Spacing1 per 50 m
Weight≈ 4.3 kg
Catalogue No.BMH-CPS-31-M20-S
BMH LS-32
LS-32 · every position, every time

Limit / travel switch

A roller lever signals the position of a tripper car or any moving equipment. The lever swings up to ~65° each way — overtravel does not damage the switch.

ActuationRoller lever Ø50, both directions
Trip point18° ± 2°, travel up to ≈ 65°
ApplicationTripper position
Weight≈ 3.5 kg
Catalogue No.BMH-CPS-32-M20-S

Series specifications

Contacts2 NO + 2 NC, positive opening
StandardIEC/EN 60947-5-1
AC-15 rating24 V 10 A · 250 V 6 A
DC-13 rating24 V 8 A · 48 V 2 A
Temperature−45 … +85 °C
Ingress protectionIP65
Cable entries3 × M20×1.5 (opt. M25, PG21)
Mounting4 × Ø9 mm, 195 × 105 mm

Order code: BMH-CPS-31-M20-S

Model 31 — pull-cord, 32 — limit · entry M20 / M25 / P21 · fasteners S — standard, X — AISI 316L

Catalogue No.Description
BMH-CPS-31-M20-SPull-cord, standard
BMH-CPS-32-M20-SLimit, standard
BMH-CPS-K5050 m cord kit
BMH-CPS-SP-L31Pull-cord switch lever
BMH-CPS-SP-R50Roller lever Ø50
BMH-CPS-SP-MSSPDT microswitch
CPS brochure (PS-31 / LS-32), PDF:⬇ Russian⬇ English
02 · Emergency stop · EPK-30 series

Pull. Stop. Lock.

A pull-cord switch in a cast aluminium housing with manual reset. A single pull on the cord along the conveyor opens the stop circuit and latches the mechanism. The belt stays stopped until the switch is reset by hand on site.

Аварийный тросовый выключатель BMH EPK-30
2 NO + 2 NCStop and alarm
30°Trip angle
Cast AlYellow, heavy-duty
Made to orderActuator handle to your specification
Stop from the walkwayThe cord is within reach along the whole protected zone: anyone can stop the conveyor right where they stand.
Deliberate resetAfter the cord is released the switch stays latched. Reset is manual only, once the cause has been found.
Stop + alarmSeparate contacts for the stop circuit and for the alarm to the control room or SCADA.
ReadyThe cord is tensioned, the stop contact is closed, the conveyor can run.
Cord pulledThe actuator turns ~30°, the stop contacts open and the mechanism latches.
Cord releasedThe switch stays latched — the belt cannot be restarted remotely.
Manual resetCause cleared — reset lever on the switch. Restart only by a separate command.

Technical data

Operating principleA pull on the cord turns the actuator
Trip angle30°, mechanical stop at 60°
ResetManual lever
Contacts2 NO + 2 NC
HousingCast aluminium, signal yellow
Temperature−30 … +75 °C
Humidityup to 85 %
Cable entryM20 × 1.5

Order code: BMH-EPK-30-S-M20

Handle: S — standard, C — made to order

Catalogue No.Description
BMH-EPK-30-S-M20Switch, standard handle
BMH-EPK-30-C-M20Switch, custom handle
BMH-EPK-CKCord kit: cord, eye bolts, thimbles, clamps, spring
BMH-EPK-SP-RLReset lever assembly
BMH-EPK-SP-CBContact block
✓ Releasing the cord or resetting the switch never starts the conveyor. Broken or slack cord detection, if needed, is provided by a separate device.
EPK-30 brochure, PDF:⬇ Russian⬇ English
03 · Belt misalignment monitoring · BRS-2 series

Belt drifting? Alarm first. Then stop.

A roller switch that watches the belt edge. When the belt starts to drift it warns the operator, and stops the conveyor only if the belt keeps running off. It protects the belt, the steelwork and the shift crew from spillage clean-up.

Выключатель схода ленты BMH BRS-2
10° / 20°Alarm / stop
2 × SPDTSeparate contacts
−50…+80 °CFor the steppe and the Far North
NEMA 4XOption for wet areas
Protects the beltCatches misalignment before the belt edge tears or the belt starts rubbing on the structure.
Two stagesAlarm at 10°, stop at 20°: the operator has time to react before shutdown.
Self-resettingWhen the belt runs straight the lever returns by itself — no need to walk the gallery to reset it.
Belt running straightThe roller does not touch the belt edge, clearance ~25 mm. Both contacts in the normal position.
Belt driftingThe belt edge deflects the roller by 10° — contact 1 operates and the operator is alerted.
Drift continuesAt 20° contact 2 operates and the conveyor stops before any damage.
Belt back on trackThe lever returns by itself. Restart according to plant procedure.

Technical data

PrincipleThe belt edge deflects the roller lever
Contacts2 × SPDT: alarm + stop
Trip point10° alarm · 20° stop
Lever positionAdjustable in 22.5° steps
Operating force≈ 22 N
Clearance to belt≈ 25 mm
ReturnAutomatic, mechanical
Temperature−50 … +80 °C
EnclosureNEMA 4, NEMA 4X optional
Cable entries2 × M20 × 1.5 or 2 × ¾» NPT
Mounting4 × Ø10 mm, 171 × 98.5 mm

Order code: BMH-BRS-2-M-4X

Entry: M — M20, N — ¾» NPT · Enclosure: 4 — NEMA 4, 4X — NEMA 4X

Catalogue No.Description
BMH-BRS-2-M-4M20 entries, NEMA 4
BMH-BRS-2-M-4XM20 entries, NEMA 4X
BMH-BRS-2-N-4¾» NPT entries, NEMA 4
BMH-BRS-SP-RARoller and lever assembly
BMH-BRS-SP-CBContact block
BMH-BRS-SP-GSSeal and gland kit

Install switches in pairs, one on each side of the belt: at the head and tail pulleys, at transfer points and along long sections.

BRS-2 brochure, PDF:⬇ Russian⬇ English
04 · Level and blockage monitoring · TS-39 series

Bin full? Chute blocked? Know instantly.

A cast-iron tilt switch suspended in the material path. When ore or bulk material tilts it away from vertical, the contact opens and the control system reacts before spillage, overfilling or a conveyor pile-up begins.

Датчик наклона BMH TS-39
IP67Sealed probe
−50…+80 °CFor the steppe and the Far North
5 AAt 220 V AC / 24 V DC
6 mStandard cable
High levelBins, hoppers, stockpiles and silos: a reliable high-level signal with no setup.
Chute blockageTransfer points and discharge chutes: cuts the feed before material spills onto the belt.
Flow / no flowIn a falling stream it confirms material movement with simple relay logic.
Normal operationThe probe hangs freely above the material. Contact closed, circuit healthy.
Material arrivesMaterial tilts the probe more than ~15° — the contact opens: alarm, feeder stop.
Back to normalThe material has gone, the probe returns to vertical under its own weight — the system is ready to start.

Technical data

Contact1 × NC, opens on tilt
Trip angle≈ 15° from vertical
HousingCast iron, chrome-plated
Probe length195 mm (overall 230 mm)
ConnectionM20 × 1.5, 50 mm
Cable6 m standard, longer to order
Contact rating5 A at 220 V AC · 5 A at 24 / 12 V DC
Temperature−50 … +80 °C
Ingress protectionIP67

Order code: BMH-TS-39-C-06

Cable: 06 / 10 / 15 m

Catalogue No.Description
BMH-TS-39-C-06Tilt switch, 6 m cable
BMH-TS-39-C-10Tilt switch, 10 m cable
BMH-TS-39-C-15Tilt switch, 15 m cable
BMH-TS-MKMounting kit: bracket and 1 m chain

Hang it from a bracket or a short chain on a rigid support — never by the cable.

✓ Normally closed contact: a broken cable, loose terminal or power loss opens the circuit just like a tilt — the controller sees a fault, not a false “all clear”.
TS-39 brochure, PDF:⬇ Russian⬇ English
People’s safety

People first. The belt can wait.

Most conveyor injuries happen at pulleys, idlers and transfer points — often during clean-up, inspection or clearing a blockage. The entire BMH protection range is built around one idea: anyone who sees a hazard must be able to stop the belt instantly, and nobody can restart it while people are in the danger zone.

An emergency stop is not a substitute for isolationSwitches stop the conveyor in an emergency, but they do not replace guarding or lockout/tagout (LOTO). Isolate and lock out the drive before any maintenance. The stop circuit is designed and tested for each specific conveyor.
Download brochures

Documentation for engineers

We will select protection for your conveyor

Send us the length, layout and transfer points — a BMH engineer will select switches, sensors, cord kits and spares.