Density cup
A cup of exact volume with overflow holes. The slurry mass in grams equals its density. Manufactured in Kazakhstan, 30–40 calendar days after the order is agreed with the Customer, 12-month warranty.

Application
- Mill and classifier discharges
- Flotation and thickener feed
- Verification of in-line density meters
How it works
The cup is overfilled with slurry: the excess drains through the overflow holes, leaving exactly the nominal volume. The cup is weighed and the tare subtracted. For a 1000 cm³ cup the mass in grams equals the density in g/L; for 500 cm³ it is multiplied by 2. % solids is calculated from the slurry density and the solids density. The cup is calibrated with water, and its volume is marked on the nameplate.
Design and materials
- AISI 304 cup, 1 mm sheet, longitudinal TIG seam
- 4 overflow holes at one height
- Water-calibrated, accuracy ±2 cm³
- Bail for filling from a stream
- Nameplate with volume and tare mass
Sizes
| № | Model | Volume, cm³ | Ø × H, mm | Tare, g | Weight, kg |
|---|---|---|---|---|---|
| 1 | SP-500 | 500 | 88 × 100 | ≈180 | ≈0,2 |
| 2 | SP-1000 | 1000 | 110 × 125 | ≈260 | ≈0,3 |
| 3 | SP-2000 | 2000 | 140 × 158 | ≈420 | ≈0,45 |
How to choose
- 1000 cm³ — plant standard
- 500 cm³ — for valuable or small samples
- 2000 cm³ — for coarse slurry and high accuracy
- Scales with accuracy of 1 g or better
Scope of supply
- Cup
- Data sheet with tare mass and % solids table
Made-to-order options
- Volume 0.5–2 L
- Calibration for your scales
- Handle and spout for sampling from a stream
Request a commercial proposal
BMH samplers are designed by the BMH process engineering department and design office. Tell us the material, particle size, sampling point and required size, and we will prepare a commercial proposal. Email: sales@bmhsolutions.kz, phone: +7 702 245 00 32.